1. UREE-kit 250 ml-2 buc,pentru Analizorul A15
COMPOZITIE
A.Reactiv: Tris 100 mmol/l, 2-oxoglutarat 5.6 mmol/l, ureaza >140 U/ml, glutamat dehidrogenaza>140 U/ml, etilenglicol 220 g/l, azida de sodiu 9.5 g/l, pH 8.0
B.Reactiv: NADH 1.5 mmol/l, azida de sodiu 9.5 g/l
S.Standard glucoza/uree/creatinina. Glucoza 100 mg/dl, uree 50mg/dl ( 8.3 mmol/l, BUN 23.3 mg/dl), creatinina 2 mg/dl.Standard primar lichid.
ECHIPAMENT ADITION...
1. UREE-kit 250 ml-2 buc,pentru Analizorul A15
COMPOZITIE
A.Reactiv: Tris 100 mmol/l, 2-oxoglutarat 5.6 mmol/l, ureaza >140 U/ml, glutamat dehidrogenaza>140 U/ml, etilenglicol 220 g/l, azida de sodiu 9.5 g/l, pH 8.0
B.Reactiv: NADH 1.5 mmol/l, azida de sodiu 9.5 g/l
S.Standard glucoza/uree/creatinina. Glucoza 100 mg/dl, uree 50mg/dl ( 8.3 mmol/l, BUN 23.3 mg/dl), creatinina 2 mg/dl.Standard primar lichid.
ECHIPAMENT ADITIONAL
•Analizor A15, Ser, plasma sau urina, recoltate prin proceduri standard.
CARACTERISTICI METROLOGICE
•Limita de detectie:2.5 mg/dl uree = 1.6 mg/dl BUN = 0.42 mmol/l uree
•Limita linearitatii: 300 mg/dl = 140 mg/dl BUN = 50 mmol/l uree. Pentru valori mai mari diluati proba 1/2 cu apa distilata si repetati masurarea
•Repetabilitate ( in cadrul unei serii de masurari)
Concentratie medie uree CV n
42 mg/dl = 7.0 mmol/l 3.3% 20
137 mg/dl = 22.7 mmol/l 1.9% 20
•Reproductibilitate( de la o serie de masurari la alta).
Concentratie medie uree CV n
42 mg/dl = 7.0 mmol/l 4.3% 25
137 mg/dl = 22.7 mmol/l 2.8% 25
•Sensibilitate: 1.8 m?A*dl/mg = 10.8 m?A*l/mmol
•Veridicitate: rezultatele obtinute cu acest reactiv nu au aratat diferente sistematice prin comparatie cu reactivi de referinta( observatia 2).Detalii ale experimentelor comparative sunt disponibile la cerere.
•Interferente: lipemia (trigliceride <10 g/l) si bilirubina (<20 mg/dl) nu interfera.Hemoliza (hemoglobina 5 g/l) si amoniacul in concentratii crescute interfera.Alte medicamente si substante pot cauza interferente
2. GGT-KIT 200 ML-2 buc pentru analizorul A15
CONTINUT
A. Reactiv 1 x 40 ml 1 x 160 ml
B. Reactiv 1 x 10 ml 1 x 40 ml
COMPOZITIE
A.Reactiv: Glicilglicina 206.25 mmol/l, hidroxid de sodiu 130 mmol/ml, pH 7.9
B.Reactiv: gama-glutamil-3-carboxi-4-nitroanilina 32.5 mmol/l.
CARACTERISTICI METROLOGICE
•Limita de detectie:1.6 U/l = 27nkat/l
•Limita linearitatii: 300 U/l = 5000nkat/l. Pentru valori mai mari diluati proba 1/2 cu apa distilata si repetati masurarea
•Repetabilitate ( in cadrul unei serii de masurari)
Concentratie medie CV n
31 U/l=517nkat/l 1.6% 20
99 U/l= 1650nkat/l 0.5% 20
•Reproductibilitate( de la o serie de masurari la alta).
Concentratie medie CV n
31 U/l=517nkat/l 4.8% 25
99 U/l= 1650nkat/l 1.4% 25
•Sensibilitate:0.719 ?mA*l/U*min = 0.043 ?mA*l/µkat*min
•Veridicitate: rezultatele obtinute cu acest reactiv nu au aratat diferente sistematice prin comparatie cu reactivi de referinta.Detalii ale experimentelor comparative sunt disponibile la cerere.
•Interferente:hemoglobina(>5g/l), lipemia (trigliceride >4 g/l) si bilirubina (>10 g/l) pot afecta rezultatele. Alte medicamente si substante pot cauza interferente4.
Aceste caracteristici metrologice au fost obtinute utilizand un analizor.Rezultatele pot varia daca se utilizeaza un instrument diferit sau proceduri manuale.
ECHIPAMENT ADITIONAL
•Analizor
3. AST(TGO)KIT 1000ML-1 buc
Biochimie - GOT (AST), mod. IFCC, liquid stable, 2 reactivi, 1000ml: R1=800ml+R2=200ml, pentru analizorul A15 CE mark, se lucr