Feedback
I.D.: 87853888

AVITI instrument (Element Biosciences)

Data publicarii
05.10.23 Exista 1.077 licitatii active asemanatoare. Inregistrati-va pentru a avea acces la acestea.
Coduri CPV
38000000
Locul realizarii:
  • Descarca
  • Tipareste
  • Observatii
    Adaugati favorite, invitatii si note. Aceste functii sunt disponibile doar pentru utilizatorii logati in platforma. Logati-va sau inregistrati-va la o Testare Gratuita pentru a avea acces.
  • Trimite
Descriere:
Justification for the direct purchase. The justification must be based on one of the preconditions mentioned in the procurement act (1397/2016).( 40§, 41§, 110§, 119§). 40§ 2) only a certain supplier can implement the procurement for a technical reason, or for a reason related to protecting an exclusive right; it shall be a further condition that there are no reasonable alternatives or substitute solutions...
Justification for the direct purchase. The justification must be based on one of the preconditions mentioned in the procurement act (1397/2016).( 40§, 41§, 110§, 119§). 40§ 2) only a certain supplier can implement the procurement for a technical reason, or for a reason related to protecting an exclusive right; it shall be a further condition that there are no reasonable alternatives or substitute solutions, and that the absence of competition is not due to an artificial narrowing of the terms and conditions of the procurement.The DNA sequencing and genomics laboratory is planning to replace its mid output sequencing instrument.Requirements for the new instrument are:• The range of outputs are flexible with low, medium and high throughput kits.• Sequencing cycle outputs are flexible including 150, 300 and 600 cycle kits.• Range of outputs must be flexible (50Gb-600Gb+).• Long size inserts (up-to 1.5kbp) must be allowed to be used.• Instrument must have two independent flow cells to allow its use in parallel or independently like two sequencers in one.• Linear libraries must be able to be loaded to the flow cell and the library circulation and RCA be made onboard.• It must have sequencing accuracy of very high quality (average Q30 >90%).• Instrument must use rolling circle amplification (RCA) that minimizes common amplification errors: no PCR error propagation, negligible index hopping, low duplicate rates, low AT/GC bias and no optical duplicates. • Instrument must be able to be handle protein and cell capture using the same apparatus and similar slides.The AVITI System is the only instrument in the market that has all the features that are required for the needed sequencing service.
Inregistrati-va acum pentru un test gratuit de 7 zile
si veti putea vizualiza aceasta licitatie si multe altele asemanatoare!
 

De ce licitatie-publica.ro?

  • Oportunitati de afaceri selectionate
    individual

  • Anunturi scanate si actualizate
    din peste 3200 surse publice si private

  • Manager de cont personal - chiar si
    in timpul testarii gratuite

  • Transmiterea zilnica a anunturilor noi

Contul meu